Test Equipment Rental / Rent / Lease to own at JM Test Systems
Follow JM Test Systems on Facebook View JM Test Systems videos at YouTube

SEARCH TEST EQUIPMENT RENTAL PRODUCTS

Application Notes / Case Studies

Calibration and Repair Services offered by JM Test Systems

Test Equipment Sales offered by JM Test Systems

Electrical safety products offered by JM Test Systems

Process Instrumentation products offered by JM Test Systems

Electrical Test Equipment by Product - Recommended by JM Test Systems

We offer two easy ways to search for your electrical test equipment:

Electrical Test Equipment Product Type

AC Voltage drop test - Multimeter Doble F6150 Relay Network protector relays-relay test set
Applied voltage test - Megger /AC  Hipot Doble F6150 Relay ** Phase rotation, phasing and synchronized test- Phase rotation & Phasing meter
Baseline diagnostics test- Tan delta Partial discharge, VLF HV TDB-60 Electrical multimeter Phase to phase stator resistance test?-DLRO
BITE Test Excitation test- CT Test Set Vanguard EZCT Point to point test- Ground test-AEMC Ground Stake
Cable attenuation loss measurement test- Optical power loss test set? Fall of potential test- Ground test-AEMC Ground Stake Polarity Test-CT Test Set Vanguard EZCT
Cable length measurement-OTDR Ground fault pickup and time delay- Primary Current Injection- HC1 Or larger Power factor or dissipation factor test- Doble M4000
Calibrate relays- Doble F6150 Grounding Connection test- Ground tester-AEMC 3731 Ratio-verification test- CT Test Set Vanguard EZCT
Capacitance measurement-Multimeter High Current recloser test set- breaker test set Relay calibration- Doble F6150
Clamp ampmeter- Fluke clamp meter High potential test- DC Hipot Resistance measurement test-low resistance ohmmeter-DLRO / Ductor
Connector and splice attenuation loss measurement test- Optical power loss test set? Hipot Test- DC Resistance measurement-Multimeter
Connector and splice integrity test- OTDR Input circuit breaker- primary injection Resistance temperature detector test-RTD-Decade Box
Contact / pole resistance test set - DLRO Ductor Instantaneous pickup- Primary Current Injection- HC1 Or larger Short time pickup and delay-Primary Current Injection- HC1 Or larger
Control wiring insulation resistance measurement-megger Insulation power factor  or dissipation factor test Tip up testing- Power Factor Single Phase relay test set
CT Test Set Insulation resistance test for control wiring- 500v or 1,000v megger Specific Gravity test-Hydrometer
Current Injection-High Current test set Internal ohmic measurement test- Megger BITE unit Test circuit breakers- High Current Test Set-HC1 or HC2
Current or voltage output Liquid dielectric test for insulating liquid according to ASTM standard Test surge protection devices- Baker or Electrom
Current transformer ratios- single or 3 phase TTR Liquid dielectric test-OIL Test set Thermographic survey-thermal imager
DC dielectric withstand voltage- DC Hipot Long time pickup and delay- Primary Current Injection-HC1 Or larger Time delay of the ground fault protective device-Relay Test Set
DC undervoltage trip level Multimeter Low resistance ohm meter- DLRO-Ductor Time travel analysis- Vanguard CT-7000
Dew point analyzer for tank gases-Cosa XPDM Measure intercell connection resistances- Megger BITE Unit Torque wrench
Dewpoint Analyzer for SF6 Gas-Cosa XPDM Measuring Insulation resistance- megger Turns ratio test- single or 3 phase TTR
Dewpoint Analyzer- Test for SF6 Gas Minimum pick up voltage test Vacuum bottle integrity test / dielectric withstand voltage test- AC Hipot
Dielectric breakdown voltage test-oil test set Minimum pickup voltage test-Secondary Test Kits Vibration test- Fluke 810
Dielectric withstand test Hipots / VLF Hipots Minimum pickup voltage test-Secondary Test Kits-specific to breaker Winding insulation power factor or dissipation factor test- Power factor
Dielectric withstand voltage test- AC Hipot PFT-503 Motor overload relay elements- Injecting primary current Winding resistance test set- WRM
Dielectric withstand voltage test- DC Hipot Multimeter Winding to ground insulation resistance test-WRM
Dielectric withstand voltage Test-AC / DC HIPOT ** Timing relay, distance relay, volts/hertz relay, sync check relay, undervoltage relay, directional power relay, loss of field - impedance relay, current balance relay, negative sequence current relay, phase sequence or phase balance voltage relay, thermal replicate relay, termperature RTD relay, instantaneious overcurrent relay, time over current relay, power factor relay, overvoltage relay, voltage balance relay, transformer sudden pressure relay, ground detector relay, directional overcurrent relay, reclosing relay, frequency relay, pilot wire monitor, differential

Recommended Electrical Testing Applications By Product Type

Recommended electrical test equipment and applicationsAC Voltage drop test - Multimeter

  • Rotating Machinery, DC Motors and Generators

Applied voltage test - Megger /AC  Hipot

  • Transformers, Dry Type, Air Cooled, Large

Baseline diagnostics test- Tan delta Partial discharge, VLF HV TDB-60

  • Cables, Medium and High Voltage

BITE Test

  • Emergency Systems, Uninterruptible Power Systems

Cable attenuation loss measurement test- Optical power loss test set?

  • Fiber Optic Cables

Cable length measurement-OTDR

  • Fiber Optic Cables

Return to Top

Calibrate relays- Doble F6150

  • Emergency Systems, Automatic Transfer Switches

Capacitance measurement-Multimeter

  • Capacitors and Reactors

Clamp ampmeter- Fluke clamp meter

  • Metal Enclosed Busways

Connector and splice attenuation loss measurement test- Optical power loss test set?

  • Fiber Optic Cables

Connector and splice integrity test- OTDR

  • Fiber Optic Cables

Contact / pole resistance test set - DLRO Ductor

  • Emergency Systems, Uninterruptible Power Systems
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers, SF6
  • Emergency Systems, Automatic Transfer Switches
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Switches, Cutouts
  • Network Protectors, 600-volt Class
  • Circuit Switchers
  • Motor Control, Motor Starters, Medium Voltage
  • Metal Enclosed Busways
  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage

Return to Top

Control wiring insulation resistance measurement-megger

  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Transformers, Dry Type, Air Cooled, Large

CT Test Set

  • Transformers, Dry Type , Air Cooled, Low Voltage

Current Injection-High Current test set

  • Switchgear& Switch board Assemblies

Current or voltage output-

  • Metering Devices-Microprocessor Based

Current transformer ratios- single or 3 phase TTR

  • Network Protectors, 600-volt Class

DC dielectric withstand voltage- DC Hipot

  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Transformers, Dry Type , Air Cooled, Low Voltage

DC undervoltage trip level Multimeter

  • Emergency Systems, Uninterruptible Power Systems

Dewpoint Analyzer Test for SF6 Gas-Cosa XPDM

  • Transformers, Liquid Filled
  • Circuit Breakers,SF6
  • Switches, SF6, Medium Voltage

Return to Top

Dielectric breakdown voltage test-oil test set

  • Switches, Oil, Medium-Voltage
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Liquid Filled
  • Regulating Apparatus, Voltage, Induction Regulators
  • Circuit Breakers, Oil, Medium- and High Voltage

Dielectric withstand test Hipots / VLF Hipots

  • Cables, Medium and High Voltage

Dielectric withstand voltage test- AC Hipot PFT-503

  • Metal Enclosed Busways
  • Circuit Breakers, Vacuum, Medium Voltage

Dielectric withstand voltage test- DC Hipot

  • Automatic Circuit Reclosers and Line Sectionalizers
  • Switches, Cutouts
  • Circuit Breakers, Air, Medium-Voltage
  • Motor Control, Motor Starters, Medium Voltage
  • Outdoor Bus Structures
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage

Dielectric withstand voltage Test-AC / DC HIPOT

  • Circuit Switchers
  • Circuit Breakers,SF6
  • Switchgear& Switch board Assemblies

Return to Top

Doble F6150 Relay

  • Protective Relays, Microprocessor –Based

Doble F6150 Relay (Including Timing relay, distance relay, volts/hertz relay, sync check relay, undervoltage relay, directional power relay, loss of field - impedance relay, current balance relay, negative sequence current relay, phase sequence or phase balance voltage relay, thermal replicate relay, termperature RTD relay, instantaneious overcurrent relay, time over current relay, power factor relay, overvoltage relay, voltage balance relay, transformer sudden pressure relay, ground detector relay, directional overcurrent relay, reclosing relay, frequency relay, pilot wire monitor, differential)

  • Protective Relays, Electromechanical and Solid State

 

Electrical multimeter

  • Metal Enclosed Busways
  • Transformers, Liquid Filled
  • Switchgear& Switch board Assemblies
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Cables, Low voltage, 600 volt maximum
  • Cables, Medium and High Voltage
  • Switches, SF6, Medium Voltage
  • Regulating Apparatus, Load Tap Changers
  • Rotating Machinery, Synchronous Motors and Generators

Excitation test- CT Test Set Vanguard EZCT

  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled
  • Instrument Transformers
  • Voltage Transformers

Fall of potential test- Ground test-AEMC Ground Stake

  • Grounding Systems

Ground fault pickup and time delay- Primary Current Injection- HC1 Or larger

  • Circuit Breakers, Air, Insulated-Case/Molded-Case

Grounding Connection test- Ground tester-AEMC 3731

  • Switches, Air, Low Voltage
  • Switchgear& Switch board Assemblies
  • Surge Arrestors, Medium and High voltage
  • Surge Arrestors, Low Voltage

Return to Top

High Current recloser test set- breaker test set

  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Circuit Breakers, Air, Medium-Voltage

High potential test- DC Hipot

  • Rotating Machinery, DC Motors and Generators

Hipot Test- DC

  • Transformers, Liquid Filled

Input circuit breaker- primary injection

  • Motor Control, Motor Starters, High Voltage

Instantaneous pickup- Primary Current Injection- HC1 Or larger

  • Circuit Breakers, Air, Insulated-Case/Molded-Case

Insulation power factor or dissipation factor test Tip up testing- Power Factor

  • Rotating Machinery, AC Induction Motors and Generators
  • Regulating Apparatus, Load Tap Changers
  • Rotating Machinery, Synchronous Motors and Generators

Return to Top

Insulation resistance test for control wiring- 500v or 1,000v megger

  • Outdoor Bus Structures
  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers
  • Network Protectors, 600-volt Class
  • Protective Relays, Electromechanical and Solid State
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled
  • Protective Relays, Microprocessor –Based
  • Cables, Low voltage, 600 volt maximum
  • Cables, Medium and High Voltage
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers
  • Network Protectors, 600-volt Class
  • Instrument Transformers
  • Voltage Transformers
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Ground-Fault Protection Systems, Low Voltage
  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Rotating Machinery, DC Motors and Generators
  • Motor Control, Motor Starters, Low Voltage
  • Surge Arrestors, Low Voltage
  • Surge Arrestors, Medium and High voltage
  • Capacitors and Reactors
  • Emergency Systems, Engine Generator
  • Emergency Systems, Automatic Transfer Switches
  • Regulating Apparatus, Load Tap Changers
  • Switches, Cutouts
  • Regulating Apparatus, Voltage, Induction Regulators
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Motor Control, Motor Starters, Medium Voltage
  • Switchgear& Switch board Assemblies
  • Switchgear& Switch board Assemblies

Internal ohmic measurement test- Megger BITE unit

  • Direct-Current Systems, Batteries, Valve Regulated Lead Acid

Return to Top

Liquid dielectric test for insulating liquid according to ASTM standard

  • Transformers, Liquid Filled

Liquid dielectric test-OIL Test set

  • Regulating Apparatus, Voltage, Step Voltage Regulators

Long time pickup and delay- Primary Current Injection-HC1 Or larger

  • Circuit Breakers, Air, Insulated-Case/Molded-Case

Low resistance ohm meter- DLRO-Ductor

  • Switchgear& Switch board Assemblies
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled
  • Cables, Low voltage, 600 volt maximum
  • Cables, Medium and High Voltage
  • Metal Enclosed Busways
  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage
  • Switches, Cutouts
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers
  • Network Protectors, 600-volt Class
  • Instrument Transformers
  • Metering Devices
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Regulating Apparatus, Voltage, Induction Regulators
  • Regulating Apparatus, Load Tap Changers
  • Grounding Systems
  • Ground-Fault Protection Systems, Low Voltage
  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Rotating Machinery, DC Motors and Generators
  • Motor Control, Motor Starters, Low Voltage
  • Motor Control, Motor Starters, Medium Voltage
  • Motor Control, Motor Starters, High Voltage
  • Direct-Current Systems, Batteries, Flooded Lead Acid
  • Direct-Current Systems, Batteries, Vented Nickel-Cadmium
  • Direct-Current Systems, Batteries, Valve Regulated Lead Acid
  • Surge Arrestors, Low Voltage
  • Surge Arrestors, Medium and High voltage
  • Capacitors and Reactors
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Dry Type
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Liquid Filled
  • Outdoor Bus Structures
  • Emergency Systems, Uninterruptible Power Systems
  • Emergency Systems, Automatic Transfer Switches
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil

Return to Top

Recommended electrical test equipment and applicationsMeasure intercell connection resistances- Megger BITE Unit

  • Direct-Current Systems, Batteries, Flooded Lead Acid
  • Direct-Current Systems, Batteries, Vented Nickel-Cadmium
  • Direct-Current Systems, Batteries, Valve Regulated Lead Acid

Measuring Insulation resistance- megger

  • Metal Enclosed Busways

Minimum pick up voltage test

  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil

Minimum pickup voltage test-Secondary Test Kits

  • Circuit Breakers, Air, Insulated-Case/Molded-Case

Minimum pickup voltage test-Secondary Test Kits-specific to breaker

  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers

Motor overload relay elements- Injecting primary current

  • Motor Control, Motor Starters, High Voltage

Multimeter

  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Metering Devices

Return to Top

Network protector relays-relay test set

  • Network Protectors, 600-volt Class

Phase rotation, phasing and synchronized test- Phase rotation & Phasing meter

  • Emergency Systems, Automatic Transfer Switches
  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Emergency Systems, Engine Generator
  • Metal Enclosed Busways

Phase to phase stator resistance test - DLRO

  • Rotating Machinery, AC Induction Motors and Generators

Point to point test- Ground test-AEMC Ground Stake

  • Grounding Systems

Polarity Test-CT Test Set Vanguard EZCT

  • Instrument Transformers
  • Voltage Transformers

Power factor or dissipation factor test- Doble M4000

  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled
  • Circuit Breakers, Air, Insulated-Case/Molded-Case

Return to Top

Ratio-verification test- CT Test Set Vanguard EZCT

  • Instrument Transformers
  • Voltage Transformers

Relay calibration- Doble F6150

  • Motor Control, Motor Starters, High Voltage

Resistance measurement test-low resistance ohmmeter-DLRO / Ductor

  • Metering Devices
  • Rotating Machinery, AC Induction Motors and Generators
  • Direct-Current Systems, Batteries, Valve Regulated Lead Acid
  • Ground-Fault Protection Systems, Low Voltage
  • Motor Control, Motor Starters, Low Voltage
  • Capacitors and Reactors
  • Regulating Apparatus, Load Tap Changers
  • Grounding Systems
  • Rotating Machinery, Synchronous Motors and Generators
  • Motor Control, Motor Starters, Medium Voltage
  • Motor Control, Motor Starters, High Voltage
  • Direct-Current Systems, Batteries, Vented Nickel-Cadmium
  • Surge Arrestors, Low Voltage
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Dry Type
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Liquid Filled
  • Outdoor Bus Structures
  • Emergency Systems, Uninterruptible Power Systems
  • Emergency Systems, Automatic Transfer Switches
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil
  • Instrument Transformers
  • Voltage Transformers
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Rotating Machinery, DC Motors and Generators
  • Direct-Current Systems, Batteries, Flooded Lead Acid
  • Surge Arrestors, Medium and High voltage
  • Transformers, Liquid Filled
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage
  • Switches, Cutouts
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers
  • Network Protectors, 600-volt Class
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large
  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Regulating Apparatus, Voltage, Induction Regulators
  • Switchgear& Switch board Assemblies
  • Cables, Low voltage, 600 volt maximum
  • Cables, Medium and High Voltage
  • Metal Enclosed Busways

Resistance measurement-Multimeter

  • Capacitors and Reactors

Resistance temperature detector test-RTD- Decade Box

  • Rotating Machinery, Synchronous Motors and Generators
  • Rotating Machinery, AC Induction Motors and Generators

Return to Top

Short time pickup and delay-Primary Current Injection- HC1 Or larger

  • Circuit Breakers, Air, Insulated-Case/Molded-Case

Single Phase relay test set

  • Metering Devices

Specific Gravity test-Hydrometer

  • Direct-Current Systems, Batteries, Flooded Lead Acid
  • Direct-Current Systems, Batteries, Vented Nickel-Cadmium
  • Emergency Systems, Uninterruptible Power Systems

Test circuit breakers- High Current Test Set-HC1 or HC2

  • Motor Control, Motor Starters, Low Voltage

Test surge protection devices- Baker or Electrom

  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators

Thermographic survey-thermal imager

  • Switchgear& Switch board Assemblies
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled
  • Cables, Low voltage, 600 volt maximum
  • Cables, Medium and High Voltage
  • Metal Enclosed Busways
  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage
  • Switches, Cutouts
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers
  • Network Protectors, 600-volt Class
  • Instrument Transformers
  • Metering Devices
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Regulating Apparatus, Voltage, Induction Regulators
  • Regulating Apparatus, Load Tap Changers
  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Rotating Machinery, DC Motors and Generators
  • Motor Control, Motor Starters, Low Voltage
  • Motor Control, Motor Starters, Medium Voltage
  • Motor Control, Motor Starters, High Voltage
  • Direct-Current Systems, Batteries, Flooded Lead Acid
  • Direct-Current Systems, Batteries, Vented Nickel-Cadmium
  • Direct-Current Systems, Batteries, Valve Regulated Lead Acid
  • Capacitors and Reactors
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Dry Type
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Liquid Filled
  • Outdoor Bus Structures
  • Emergency Systems, Uninterruptible Power Systems
  • Emergency Systems, Automatic Transfer Switches
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil

Return to Top

Time delay of the ground fault protective device-Relay Test Set

  • Ground-Fault Protection Systems, Low Voltage

Time travel analysis- Vanguard CT-7000

  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers,SF6
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage

Torque wrench

  • Switchgear& Switch board Assemblies
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled
  • Cables, Low voltage, 600 volt maximum
  • Cables, Medium and High Voltage
  • Metal Enclosed Busways
  • Switches, Air, Low Voltage
  • Switches, Air, Medium-Voltage, Metal Enclosed
  • Switches, Air, Medium-and High Voltage, Open
  • Switches, Oil, Medium-Voltage
  • Switches, Vacuum, Medium-Voltage
  • Switches, SF6, Medium Voltage
  • Switches, Cutouts
  • Circuit Breakers, Air, Insulated-Case/Molded-Case
  • Circuit Breakers, Air, Medium-Voltage
  • Circuit Breakers, Oil, Medium- and High Voltage
  • Circuit Breakers, Vacuum, Medium Voltage
  • Circuit Breakers,SF6
  • Circuit Switchers
  • Network Protectors, 600-volt Class
  • Instrument Transformers
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Regulating Apparatus, Voltage, Induction Regulators
  • Regulating Apparatus, Load Tap Changers
  • Grounding Systems
  • Ground-Fault Protection Systems, Low Voltage
  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Rotating Machinery, DC Motors and Generators
  • Motor Control, Motor Starters, Low Voltage
  • Motor Control, Motor Starters, Medium Voltage
  • Motor Control, Motor Starters, High Voltage
  • Direct-Current Systems, Batteries, Flooded Lead Acid
  • Direct-Current Systems, Batteries, Vented Nickel-Cadmium
  • Direct-Current Systems, Batteries, Valve Regulated Lead Acid
  • Surge Arrestors, Low Voltage
  • Surge Arrestors, Medium and High voltage
  • Capacitors and Reactors
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Dry Type
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Liquid Filled
  • Outdoor Bus Structures
  • Emergency Systems, Uninterruptible Power Systems
  • Emergency Systems, Automatic Transfer Switches
  • Automatic Circuit Reclosers and Line Sectionalizers
  • Automatic Circuit Reclosers and Line Sectionalizers-Oil

Turns ratio test- single or 3 phase TTR

  • Switchgear& Switch board Assemblies
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large
  • Transformers, Liquid Filled

Vacuum bottle integrity test / dielectric withstand voltage test- AC Hipot

  • Circuit Breakers, Vacuum, Medium Voltage
  • Regulating Apparatus, Load Tap Changers
  • Switches, Vacuum, Medium-Voltage
  • Automatic Circuit Reclosers and Line Sectionalizers
  • utomatic Circuit Reclosers and Line Sectionalizers-Oil

Vibration test- Fluke 810

  • Rotating Machinery, DC Motors and Generators
  • Rotating Machinery, AC Induction Motors and Generators
  • Rotating Machinery, Synchronous Motors and Generators
  • Emergency Systems, Engine Generator

Winding insulation power factor or dissipation factor test- Power factor

  • Regulating Apparatus, Voltage, Induction Regulators

Winding resistance test set - WRM

  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large

Winding to ground insulation resistance test - WRM

  • Regulating Apparatus, Load Tap Changers
  • Regulating Apparatus, Voltage, Step Voltage Regulators
  • Capacitors and Reactors, Reactors, Shunt and Current Limiting, Liquid Filled
  • Transformers, Dry Type , Air Cooled, Low Voltage
  • Transformers, Dry Type, Air Cooled, Large

Return to Top

Battery Impedance Test Set Ductor/DLRO Hipots/VLF Test Sets Phasing Tester Thermal Imaging Cable/Fault Locators Electrical Multimeter Kilovoltmeters Power Datalogging & Analysis TTR/Transformer Turns Ratio Testers Clamp On Meters Ground Resistance / Earth Testers Megger 1kv, 5kv, 15kv Power Factor Tester Voltage Detector CT Test Sets / Current Transform High Current Test Sets Motor Analyzers Relay Test Sets Winding Resistance Meters Battery Impedance Test Set Ductor/DLRO Hipots/VLF Test Sets Phasing Tester Thermal Imaging Cable/Fault Locators Electrical Multimeter Kilovoltmeters Power Datalogging & Analysis TTR/Transformer Turns Ratio Testers Clamp On Meters Ground Resistance / Earth Testers Megger 1kv, 5kv, 15kv Power Factor Tester Voltage Detector CT Test Sets / Current Transform High Current Test Sets Motor Analyzers Relay Test Sets Winding Resistance Meters